Smart Refrigerator to storage of blood and its components with temperature from 2° to 6°C, alarms, dialer and temperature homogenization system.
280 liters |
2°C to 6°C |
201H X 69W X 64D (cm) external |
107H X 53W X 51D (cm) internal |
4 a 5 shelves or drawers |
Triple glass door |
Optional, Emergency System for 24 or 48 hours |
Consult different autonomy options with our commercial consultants |
EXTERNAL
Vertical stainless steel CABINET with 4 swivel castors with 3 "diagonal brakes.
INTERNAL
Stainless steel CABINET equipped with 4 shelves ou drawers.
LIGHTING
Led lamps with automatic activation when opening the door and/or optional programmable timer with external access even when the door is closed.
TEMPERATURE HOMOGENIZER
The forced-air circulation ensure perfect homogenization of the temperature at all points inside the equipment. It shuts down when the door is opened.
THERMAL INSULATION
High density injected polyurethane.
DOOR
Triple glass vertical door with anti-fog system, magnetic profile seal with opening alarm.
REFRIGERATION
Through airtight compressor with CFC-free R-134 A ecological gas circulation, forced-air evaporator unit, automatic defrost system with condensate evaporation.
CONTROL PANEL
On the top of the equipment with main switch and protection fuses on the back and membrane-type front panel with soft-touch keys. Electronic microprocessed thermostat with temperature and programming parameters decimal digital display, locking system against inadvertent handling, system that re-establishes the programmed parameters even with abrupt energy variation or equipment shutdown. Filter against electromagnetic noise. Automatic function check system. Equipped with ITTC type sensors. 2.3 amperes battery to support the functions of the electronic panel, to trigger alarms and the dialer on equipment without emergency system.
VISUAL SIGNS
Visual and simultaneous display for commercial power, temperature deviations, open door, power failure and battery charge level. Electronic recorder of maximum and minimum temperatures reached.
AUDIOVISUAL ALARMS
Temperature below 2°C, temperature above 8°C (or 6°C for storage of blood and its components), or adjustable by user. Alarms for electric power cut, open door, inhibit key to silence the buzzer for 15 minutes, or adjustable by user. Equipped with alarm simulator.
WORKING RANGE
Minimum of 2°C and maximum of 8°C (or 6°C for storage of blood and its components), with set point at 4°C, or adjustable by user, with a variation of + -0.1°C.
TEMPERATURE RECORDER
Electronic recorder of maximum and minimum temperatures reached.
SECURITY SYSTEM
Thermostat installed in parallel with the electronic controller of the equipment, automatically taking control of compressor functions whenever the electronic control fails.
DIALER
Automatic system that makes telephone calls via telephone switchboard or direct fixed line for up to six numbers whenever the equipment alarms at critical temperature.
MANAGEMENT SOFTWARE
Real time follow-up, access to charts and reports remotely via mobile application, including retroactive data, allowing management of the refrigerator via Internet with RS232/485/DB-25 serial output.
OPERATION
Bivolt 127/220 VOLTS 50/60 Hz
WARRANTY
1 year.